Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.538
Filtrar
1.
Radiat Oncol ; 19(1): 48, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622628

RESUMO

BACKGROUND: Tumor regression and organ movements indicate that a large margin is used to ensure target volume coverage during radiotherapy. This study aimed to quantify inter-fractional movements of the uterus and cervix in patients with cervical cancer undergoing radiotherapy and to evaluate the clinical target volume (CTV) coverage. METHODS: This study analyzed 303 iterative cone beam computed tomography (iCBCT) scans from 15 cervical cancer patients undergoing external beam radiotherapy. CTVs of the uterus (CTV-U) and cervix (CTV-C) contours were delineated based on each iCBCT image. CTV-U encompassed the uterus, while CTV-C included the cervix, vagina, and adjacent parametrial regions. Compared with the planning CTV, the movement of CTV-U and CTV-C in the anterior-posterior, superior-inferior, and lateral directions between iCBCT scans was measured. Uniform expansions were applied to the planning CTV to assess target coverage. RESULTS: The motion (mean ± standard deviation) in the CTV-U position was 8.3 ± 4.1 mm in the left, 9.8 ± 4.4 mm in the right, 12.6 ± 4.0 mm in the anterior, 8.8 ± 5.1 mm in the posterior, 5.7 ± 5.4 mm in the superior, and 3.0 ± 3.2 mm in the inferior direction. The mean CTV-C displacement was 7.3 ± 3.2 mm in the left, 8.6 ± 3.8 mm in the right, 9.0 ± 6.1 mm in the anterior, 8.4 ± 3.6 mm in the posterior, 5.0 ± 5.0 mm in the superior, and 3.0 ± 2.5 mm in the inferior direction. Compared with the other tumor (T) stages, CTV-U and CTV-C motion in stage T1 was larger. A uniform CTV planning treatment volume margin of 15 mm failed to encompass the CTV-U and CTV-C in 11.1% and 2.2% of all fractions, respectively. The mean volume change of CTV-U and CTV-C were 150% and 51%, respectively, compared with the planning CTV. CONCLUSIONS: Movements of the uterine corpus are larger than those of the cervix. The likelihood of missing the CTV is significantly increased due to inter-fractional motion when utilizing traditional planning margins. Early T stage may require larger margins. Personal radiotherapy margining is needed to improve treatment accuracy.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Pelve/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica
3.
Methods Cell Biol ; 185: 99-113, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38556454

RESUMO

Radiotherapy is a crucial treatment modality for cancer patients, with approximately 60% of individuals undergoing ionizing radiation as part of their disease management. In recent years, there has been a growing trend toward minimizing irradiation fields through the use of image-guided dosimetry and innovative technologies. These advancements allow for selective irradiation, delivering higher local doses while reducing the number of treatment sessions. Consequently, computer-assisted methods have significantly enhanced the effectiveness of radiotherapy in the curative and palliative treatment of various cancers. Although radiation therapy alone can effectively achieve local control in some cancer types, it may not be sufficient for others. As a result, further preclinical research is necessary to explore novel approaches including new schedules of radiotherapy treatments. Unfortunately, there is a concerning lack of correlation between clinical outcomes and experiments conducted on mouse models. We hypothesize that this disparity arises from the differences in irradiation strategies employed in preclinical studies compared to those used in clinical practice, which ultimately affects the translatability of findings to patients. In this study, we present two comprehensive radiotherapy protocols for the treatment of orthotopic melanoma and glioblastoma tumors. These protocols utilize a small animal radiation research platform, which is an ideal radiation device for delivering localized and precise X-ray doses to the tumor mass. By employing these platforms, we aim to limit the side effects associated with irradiating healthy surrounding tissues. Our detailed protocols offer a valuable framework for conducting preclinical studies that closely mimic clinical radiotherapy techniques, bridging the gap between experimental results and patient outcomes.


Assuntos
Glioblastoma , Radioterapia Guiada por Imagem , Camundongos , Humanos , Animais , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Glioblastoma/patologia , Glioblastoma/radioterapia , Modelos Animais de Doenças
4.
BMC Cancer ; 24(1): 374, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528456

RESUMO

BACKGROUND: Chemo-radiotherapy with curative intent for anal cancer has high complete remission rates, but acute treatment-related gastrointestinal (GI) toxicity is significant. Toxicity occurs due to irradiation of surrounding normal tissue. Current radiotherapy requires the addition of large planning margins to the radiation field to ensure target coverage regardless of the considerable organ motion in the pelvic region. This increases the irradiated volume and radiation dose to the surrounding normal tissue and thereby toxicity. Online adaptive radiotherapy uses artificial intelligence to adjust the treatment to the anatomy of the day. This allows for the reduction of planning margins, minimizing the irradiated volume and thereby radiation to the surrounding normal tissue.This study examines if cone beam computed tomography (CBCT)-guided oART with daily automated treatment re-planning can reduce acute gastrointestinal toxicity in patients with anal cancer. METHODS/DESIGN: The study is a prospective, single-arm, phase II trial conducted at Copenhagen University Hospital, Herlev and Gentofte, Denmark. 205 patients with local only or locally advanced anal cancer, referred for radiotherapy with or without chemotherapy with curative intent, are planned for inclusion. Toxicity and quality of life are reported with Common Terminology Criteria of Adverse Events and patient-reported outcome questionnaires, before, during, and after treatment. The primary endpoint is a reduction in the incidence of acute treatment-related grade ≥ 2 diarrhea from 36 to 25% after daily online adaptive radiotherapy compared to standard radiotherapy. Secondary endpoints include all acute and late toxicity, overall survival, and reduction in treatment interruptions. RESULTS: Accrual began in January 2022 and is expected to finish in January 2026. Primary endpoint results are expected to be available in April 2026. DISCUSSION: This is the first study utilizing online adaptive radiotherapy to treat anal cancer. We hope to determine whether there is a clinical benefit for the patients, with significant reductions in acute GI toxicity without compromising treatment efficacy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05438836. Danish Ethical Committee: H-21028093.


Assuntos
Neoplasias do Ânus , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Qualidade de Vida , Estudos Prospectivos , Inteligência Artificial , Neoplasias do Ânus/radioterapia , Neoplasias do Ânus/etiologia , Resultado do Tratamento , Planejamento da Radioterapia Assistida por Computador/métodos , Diarreia/etiologia , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Ensaios Clínicos Fase II como Assunto
5.
J Appl Clin Med Phys ; 25(4): e14326, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38497554

RESUMO

PURPOSE: In radiation therapy, surface guidance can be used for patient setup and intra-fraction motion monitoring. The surface guided radiation therapy (SGRT) system from Varian Medical systems, IDENTIFYTM, consists of three pods, including cameras and a random pattern projector, mounted on the ceiling. The information captured by the cameras is used to make a reconstruction of the surface. The aim of the study was to assess the technical performance of this SGRT system on a closed-bore linac. METHODS: Phantom measurements were performed to assess the accuracy, precision, reproducibility and temporal stability of the system, both in align and in load position. Translations of the phantoms in lateral, longitudinal, and vertical direction, and rotations around three axes (pitch, roll and yaw) were performed with an accurate, in-house built, positioning stage. Different phantom geometries and different surface colors were used, and various ambient light intensities were tested. RESULTS: The accuracy of the IDENTIFYTM system at the closed-bore linac was 0.07 mm and 0.07 degrees at load position, and 0.06 mm and 0.01 degrees at align position for the white head phantom. The precision was 0.02 mm and 0.02 degrees in load position, and 0.01 mm and 0.02 degrees in align position. The accuracy for the Penta-Guide phantom was comparable to the white head phantom, with 0.06 mm and 0.01 degrees in align position. The system was slightly less accurate for translations of the CIRS lung phantom in align position (0.20 mm, 0.05 degrees). Reproducibility measurements showed a variation of 0.02 mm in load position. Regarding the temporal stability, the maximum drift over 30 min was 0.33 mm and 0.02 degrees in load position. No effect of ambient light level on the accuracy of the IDENTIFYTM system was observed. Regarding different surface colors, the accuracy of the system for a black phantom was slightly worse compared to a white surface, but not clinical relevant. CONCLUSION: The IDENTIFYTM system can adequately be used for motion monitoring on a closed-bore linac with submillimeter accuracy. The results of the performed measurements meet the clinical requirements described in the guidelines of the AAPM and the ESTRO.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Reprodutibilidade dos Testes , Radioterapia Guiada por Imagem/métodos , Imagens de Fantasmas , Posicionamento do Paciente/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
6.
Radiat Oncol ; 19(1): 21, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38347554

RESUMO

BACKGROUND: The dosimetric effect of setup uncertainty and tissue deformations in left-sided whole-breast irradiation with complementary surface-guided radiotherapy (SGRT) and cone-beam computed tomography (CBCT) setup was evaluated. METHOD: Treatment courses of 40.05 Gy prescribed dose in 15 fractions were simulated for 29 patients by calculating the dose on deformed CT images, that were based on daily CBCT images, and deforming and accumulating the dose onto the planning CT image. Variability in clinical target volume (CTV) position and shape was assessed as the 95% Hausdorff distance (HD95) between the planning CTV and deformed CTV structures. DVH metrics were evaluated between the planned and simulated cumulative dose distributions using two treatment techniques: tangential volumetric modulated arc therapy (tVMAT) and conventional 3D-conformal radiotherapy (3D-CRT). RESULTS: Based on the HD95 values, the variations in CTV shape and position were enclosed by the 5 mm CTV-PTV margin in 85% of treatment fractions using complementary CBCT and SGRT setup. A residual error of 8.6 mm was observed between the initial SGRT setup and CBCT setup. The median CTV V95% coverage was 98.1% (range 93.1-99.8%) with tVMAT and 98.2% (range 84.5-99.7%) with 3D-CRT techniques with CBCT setup. With the initial SGRT-only setup, the corresponding coverages were 96.3% (range 92.6-99.4%) and 96.6% (range 84.2-99.4%), respectively. However, a considerable bias in vertical residual error between initial SGRT setup and CBCT setup was observed. Clinically relevant changes between the planned and cumulative doses to organs-at-risk (OARs) were not observed. CONCLUSIONS: The CTV-to-PTV margin should not be reduced below 5 mm even with daily CBCT setup. Both tVMAT and 3D-CRT techniques were robust in terms of dose coverage to the target and OARs. Based on the shifts between setup methods, CBCT setup is recommended as a complementary method with SGRT.


Assuntos
Radioterapia Conformacional , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada de Feixe Cônico/métodos
7.
Radiother Oncol ; 193: 110120, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311029

RESUMO

PURPOSE: Children who require radiation therapy (RT) should ideally be treated awake, without anaesthesia, if possible. Audiovisual distraction is a known method to facilitate awake treatment, but its effectiveness at keeping children from moving during treatment is not known. The aim of this study was to evaluate intrafraction movement of children receiving RT while awake. METHODS: In this prospective study, we measured the intrafraction movement of children undergoing treatment with fractionated RT, using pre- and post-RT cone beam CT (CBCT) with image matching on bony anatomy. Study CBCTs were acquired at first fraction, weekly during RT, and at last fraction. The primary endpoint was the magnitude of vector change between the pre- and post-RT scans. Our hypothesis was that 90 % of CBCT acquisitions would have minimal movement, defined as <3 mm for head-and-neck (HN) treatments and <5 mm for non-HN treatments. RESULTS: A total of 65 children were enrolled and had evaluable data across 302 treatments with CBCT acquisitions. Median age was 11 years (range, 2-18; 1st and 3rd quartiles 7 and 14 years, respectively). Minimal movement was observed in 99.4 % of HN treatments and 97.2 % of non-HN treatments. The study hypothesis of >90 % of evaluations having minimal movement was met. Children who were age >11 years moved less at initial evaluation but tended to move more as a course of radiation progressed, as compared to children who were younger. CONCLUSION: Children receiving RT with audiovisual distraction while awake had small magnitudes of observed intrafraction movement, with minimal movement in >97 % of observed RT fractions. This study validates methods of anaesthesia avoidance using audiovisual distraction for selected children.


Assuntos
Anestesia , Radioterapia Guiada por Imagem , Humanos , Criança , Estudos Prospectivos , Movimento , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos
8.
Clin. transl. oncol. (Print) ; 26(2): 424-433, feb. 2024.
Artigo em Inglês | IBECS | ID: ibc-230187

RESUMO

Introduction To guarantee treatment reproducibility and stability, immobilization devices are essential. Additionally, surface-guided radiation therapy (SGRT) serves as an accurate complement to frameless stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) by aiding patient positioning and real-time monitoring, especially when non-coplanar fields are in use. At our institute, we have developed a surface-guided SRS (SG-SRS) workflow that incorporates our innovative open-face mask (OM) and mouth bite (MB) to guarantee a precise and accurate dose delivery. Methods This study included 40 patients, and all patients were divided into closed mask (CM) and open-face mask (OM) groups according to different positioning flow. Cone beam computed tomography (CBCT) scans were performed, and the registration results were recorded before and after the treatment. Then Bland–Altman method was used to analyze the consistency of AlignRT-guided positioning errors and CBCT scanning results in the OM group. The error changes between 31 fractions in one patient were recorded to evaluate the feasibility of monitoring during treatment. Results The median of translation error between stages of the AlignRT positioning process was (0.03–0.07) cm, and the median of rotation error was (0.20–0.40)°, which were significantly better than those of the Fraxion positioning process (0.09–0.11) cm and (0.60–0.75)°. The mean bias values between the AlignRT guided positioning errors and CBCT were 0.01 cm, − 0.07 cm, 0.03 cm, − 0.30°, − 0.08° and 0.00°. The 31 inter-fractional errors of a single patient monitored by SGRT were within 0.10 cm and 0.50° (AU)


Assuntos
Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Radiocirurgia , Radioterapia Guiada por Imagem/métodos , Encéfalo , Tomografia Computadorizada de Feixe Cônico/métodos , Máscaras , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes
9.
Radiother Oncol ; 190: 109963, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38406888

RESUMO

BACKGROUND: Implementation of daily cone-beam CT (CBCT) into clinical practice in paediatric image-guided radiotherapy (IGRT) lags behind compared to adults. Surveys report wide variation in practice for paediatric IGRT and technical information remains unreported. In this study we report on technical settings from applied paediatric CBCT protocols and review the literature for paediatric CBCT protocols. METHODS: From September to October 2022, a survey was conducted among 246 SIOPE-affiliated centres across 35 countries. The survey consisted of 3 parts: 1) baseline information; technical CBCT exposure settings and patient set-up procedure for 2) brain/head, and 3) abdomen. Descriptive statistics was used to summarise current practice. The literature was reviewed systematically with two reviewers obtaining consensus RESULTS: The literature search revealed 22 papers concerning paediatric CBCT protocols. Seven papers focused on dose-optimisation. Responses from 50/246 centres in 25/35 countries were collected: 44/50 treated with photons and 10/50 with protons. In total, 48 brain/head and 53 abdominal protocols were reported. 42/50 centres used kV-CBCT for brain/head and 35/50 for abdomen; daily CBCT was used for brain/head = 28/48 (58%) and abdomen = 33/53 62%. Greater consistency was seen in brain/head protocols (dose range 0.32 - 67.7 mGy) compared to abdominal (dose range 0.27 - 119.7 mGy). CONCLUSION: Although daily CBCT is now widely used in paediatric IGRT, our survey demonstrates a wide range of technical settings, suggesting an unmet need to optimise paediatric IGRT protocols. This is in accordance with the literature. However, there are only few paediatric optimisation studies suggesting that dose reduction is possible while maintaining image quality.


Assuntos
Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Adulto , Humanos , Criança , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Abdome , Tomografia Computadorizada de Feixe Cônico/métodos , Europa (Continente) , Imagens de Fantasmas , Dosagem Radioterapêutica , Literatura de Revisão como Assunto
10.
Biomed Phys Eng Express ; 10(2)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38382110

RESUMO

Objective. In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, a novel detection method for such misalignments in IGRT was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing.Approach. A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules. Digitally reconstructed radiographs (DRRs) and setup images were retrieved and co-registered according to the clinically applied alignment contained in the DICOM REG files. A semi-automated algorithm was developed to simulate patient positioning errors on the anterior-posterior (AP) and lateral (LAT) images shifted by one vertebral body. A DenseNet architecture was designed to classify either AP images individually or AP and LAT image pairs. Receiver-operator characteristic curves (ROC) and areas under the curves (AUC) were computed to evaluate the classifiers on test subsets. Subsequently, the algorithm was applied to the entire dataset in order to retrospectively determine the absolute off-by-one vertebral body error rate for planar radiograph guided RT at our institution from 2011-2021.Main results. The AUCs for the kV models were 0.98 for unpaired AP and 0.99 for paired AP-LAT. The AUC for the MV AP model was 0.92. For a specificity of 95%, the paired kV model achieved a sensitivity of 99%. Application of the model to the entire dataset yielded a per-fraction off-by-one vertebral body error rate of 0.044% [0.0022%, 0.21%] for paired kV IGRT including one previously unreported error.Significance. Our error detection algorithm was successful in classifying vertebral body positioning errors with sufficient accuracy for retrospective quality control and real-time error prevention. The reported positioning error rate for planar radiograph IGRT is unique in being determined independently of an error reporting system.


Assuntos
Radioterapia Guiada por Imagem , Corpo Vertebral , Humanos , Estudos Retrospectivos , Radiografia , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
JCO Glob Oncol ; 10: e2300336, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38386958

RESUMO

PURPOSE: The workflow of brachytherapy (BT) is an essential aspect of treatment to consider in image-guided brachytherapy (IGBT). It has an overarching effect influencing patient throughput and the number of cancer treatments that can be performed as it occupies equipment, space, and personnel. There is limited research addressing this issue. Under the International Atomic Energy Agency's Coordinated Research Activity titled IGBT for cervix cancer: An implementation study, our study analyzes various scenarios in the clinical workflow of BT delivery for cervical cancer. It aims to determine the extent to which these scenarios allow the routine implementation of IGBT. With this information, current barriers and individualized adaptations to efficient workflows can be identified to enhance the global application of IGBT, leading to better cervical cancer treatment. MATERIALS AND METHODS: A web-based poll of questions regarding practices in BT workflow was presented to 62 participants from low-, lower middle-, upper middle-, and high-income countries (19 countries). RESULTS: This study highlighted diversity in BT practices across countries, income levels, and regions. It identified variations in workflow, patient throughput, and resource availability, which can have implications for the efficiency and quality of BT treatments. Scenario A, utilizing multiple locations for the steps of the BT procedure, was the most commonly used. The availability of resources, such as imaging devices and trained personnel, varied among the participating centers and remained challenging for IGBT implementation and sustainability. CONCLUSION: The design of the BT facility plays a vital role in improving efficiency, with a dedicated BT suite contributing to an efficient workflow but limiting patient throughput, especially for high-volume centers. Although IGBT is effective, its implementation requires consideration of various logistical challenges and should be individualized.


Assuntos
Braquiterapia , Radioterapia Guiada por Imagem , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Fluxo de Trabalho , Braquiterapia/métodos , Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica
12.
Radiol Med ; 129(4): 643-652, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369638

RESUMO

BACKGROUND: Moderate hypofractionated radiotherapy is a treatment option for the cure of localized prostate cancer (PCa) patients based on the results of randomized prospective trials, but there is a clinical concern about the relatively short length of follow-up, and real-world results on outcome and toxicity based on cutting-edge techniques are lacking. The objective of this study is to present the long-term results of a large multicentric series. MATERIALS AND METHODS: We retrospectively evaluated 1325 PCa patients treated with daily volumetric image-guided hypofractionated radiotherapy between 2007 and 2020 in 16 Centers. For survival endpoints, we used Kaplan-Meier survival curves and fitted univariate and multivariable Cox's proportional hazards regression models to study the association between the clinical variables and each survival type. RESULTS: At the end of the follow-up, 11 patients died from PCa. The 15-year values of cancer-specific survival (CSS) and biochemical relapse-free survival (b-RFS) were 98.5% (95%CI 97.3-99.6%) and 85.5% (95%CI 81.9-89.4%), respectively. The multivariate analysis showed that baseline PSA, Gleason score, and the use of androgen deprivation therapy were significant variables for all the outcomes. Acute gastrointestinal (GI) and genitourinary (GU) toxicities of grade ≥ 2 were 7.0% and 16.98%, respectively. The 15-year late grade ≥ 2 GI and GU toxicities were 5% (95%CI 4-6%) and 6% (95%CI 4-8%), respectively. CONCLUSION: Real-world long-term results of this multicentric study on cutting-edge techniques for the cure of localized PCa demonstrated an excellent biochemical-free survival rate of 85.5% at 15 years, and very low rates of ≥ G3 late GU and GI toxicity (1.6% and 0.9% respectively), strengthening the results of the available published trials.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Estudos Retrospectivos , Antagonistas de Androgênios , Estudos Prospectivos , Recidiva Local de Neoplasia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos
13.
Med Phys ; 51(4): 2975-2982, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38408013

RESUMO

BACKGROUND: Dual-energy (DE)-CBCT represents a promising imaging modality that can produce virtual monoenergetic (VM) CBCT images. VM images, which provide enhanced contrast and reduced imaging artifacts, can be used to assist in soft-tissue visualization during image-guided radiotherapy. PURPOSE: This work reports the development of TIGRE-DE, a module in the open-source TIGRE toolkit for the performance of DE-CBCT and the production of VM CBCT images. This module is created to make DE-CBCT tools accessible in a wider range of clinical and research settings. METHODS: We developed an add-on (TIGRE-DE) to the TIGRE toolkit that performs DE material decomposition. To verify its performance, sequential CBCT scans at 80 and 140 kV of a Catphan 604 phantom were decomposed into equivalent thicknesses of aluminum (Al) and polymethyl-methylacrylate (PMMA) basis materials. These basis material projections were used to synthesize VM projections for a range of x-ray energies, which were then reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm. Image quality was assessed by computing Hounsfield units (HU) and contrast-to-noise ratios (CNR) for the material inserts of the phantom and comparing with the constituent 80 and 140 kV images. RESULTS: All VM images generated using TIGRE-DE showed good general agreement with the theoretical HU values of the material inserts of the phantom. Apart from the highest-density inserts imaged at the extremes of the energy range, the measured HU values agree with theoretical HUs within the clinical tolerance of ±50 HU. CNR measurements for the various inserts showed that, of the energies selected, 60 keV provided the highest CNR values. Moreover, 60 keV VM images showed average CNR enhancements of 63% and 66% compared to the 80 and 140 kV full-fan protocols. CONCLUSIONS: TIGRE-DE successfully implements DE-CBCT material decomposition and VM image creation in an accessible, open-source platform.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Raios X , Algoritmos , Radioterapia Guiada por Imagem/métodos
14.
Phys Med Biol ; 69(4)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38232395

RESUMO

Objective. The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time.Approach. We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10 min pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 s per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 min, respectively.Main results. For the full 10 min scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5 min scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 min achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively.Significance. Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5 min scan time.


Assuntos
Imagem Cinética por Ressonância Magnética , Radioterapia Guiada por Imagem , Humanos , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Radioterapia Guiada por Imagem/métodos
15.
Comput Methods Programs Biomed ; 245: 108007, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38241802

RESUMO

Purpose To minimize the various errors introduced by image-guided radiotherapy (IGRT) in the application of esophageal cancer treatment, this study proposes a novel technique based on the 'CBCT-only' mode of pseudo-medical image guidance. Methods The framework of this technology consists of two pseudo-medical image synthesis models in the CBCT→CT and the CT→PET direction. The former utilizes a dual-domain parallel deep learning model called AWM-PNet, which incorporates attention waning mechanisms. This model effectively suppresses artifacts in CBCT images in both the sinogram and spatial domains while efficiently capturing important image features and contextual information. The latter leverages tumor location and shape information provided by clinical experts. It introduces a PRAM-GAN model based on a prior region aware mechanism to establish a non-linear mapping relationship between CT and PET image domains.  As a result, it enables the generation of pseudo-PET images that meet the clinical requirements for radiotherapy. Results The NRMSE and multi-scale SSIM (MS-SSIM) were utilized to evaluate the test set, and the results were presented as median values with lower quartile and upper quartile ranges. For the AWM-PNet model, the NRMSE and MS-SSIM values were 0.0218 (0.0143, 0.0255) and 0.9325 (0.9141, 0.9410), respectively. The PRAM-GAN model produced NRMSE and MS-SSIM values of 0.0404 (0.0356, 0.0476) and 0.9154 (0.8971, 0.9294), respectively. Statistical analysis revealed significant differences (p < 0.05) between these models and others. The numerical results of dose metrics, including D98 %, Dmean, and D2 %, validated the accuracy of HU values in the pseudo-CT images synthesized by the AWM-PNet. Furthermore, the Dice coefficient results confirmed statistically significant differences (p < 0.05) in GTV delineation between the pseudo-PET images synthesized using the PRAM-GAN model and other compared methods. Conclusion The AWM-PNet and PRAM-GAN models have the capability to generate accurate pseudo-CT and pseudo-PET images, respectively. The pseudo-image-guided technique based on the 'CBCT-only' mode shows promising prospects for application in esophageal cancer radiotherapy.


Assuntos
Neoplasias Esofágicas , Tumores Neuroectodérmicos Primitivos , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos
16.
J Appl Clin Med Phys ; 25(4): e14242, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38178622

RESUMO

PURPOSE: High-quality CBCT and AI-enhanced adaptive planning techniques allow CBCT-guided stereotactic adaptive radiotherapy (CT-STAR) to account for inter-fractional anatomic changes. Studies of intra-fractional respiratory motion management with a surface imaging solution for CT-STAR have not been fully conducted. We investigated intra-fractional motion management in breath-hold Ethos-based CT-STAR and CT-SBRT (stereotactic body non-adaptive radiotherapy) using optical surface imaging combined with onboard CBCTs. METHODS: Ten cancer patients with mobile lower lung or upper abdominal malignancies participated in an IRB-approved clinical trial (Phase I) of optical surface image-guided Ethos CT-STAR/SBRT. In the clinical trial, a pre-configured gating window (± 2 mm in AP direction) on optical surface imaging was used for manually triggering intra-fractional CBCT acquisition and treatment beam irradiation during breath-hold (seven patients for the end of exhalation and three patients for the end of inhalation). Two inter-fractional CBCTs at the ends of exhalation and inhalation in each fraction were acquired to verify the primary direction and range of the tumor/imaging-surrogate (donut-shaped fiducial) motion. Intra-fractional CBCTs were used to quantify the residual motion of the tumor/imaging-surrogate within the pre-configured breath-hold window in the AP direction. Fifty fractions of Ethos RT were delivered under surface image-guidance: Thirty-two fractions with CT-STAR (adaptive RT) and 18 fractions with CT-SBRT (non-adaptive RT). The residual motion of the tumor was quantified by determining variations in the tumor centroid position. The dosimetric impact on target coverage was calculated based on the residual motion. RESULTS: We used 46 fractions for the analysis of intra-fractional residual motion and 43 fractions for the inter-fractional motion analysis due to study constraints. Using the image registration method, 43 pairs of inter-fractional CBCTs and 100 intra-fractional CBCTs attached to dose maps were analyzed. In the motion range study (image registration) from the inter-fractional CBCTs, the primary motion (mean ± std) was 16.6 ± 9.2 mm in the SI direction (magnitude: 26.4 ± 11.3 mm) for the tumors and 15.5 ± 7.3 mm in the AP direction (magnitude: 20.4 ± 7.0 mm) for the imaging-surrogate, respectively. The residual motion of the tumor (image registration) from intra-fractional breath-hold CBCTs was 2.2 ± 2.0 mm for SI, 1.4 ± 1.4 mm for RL, and 1.3 ± 1.3 mm for AP directions (magnitude: 3.5 ± 2.1 mm). The ratio of the actual dose coverage to 99%, 90%, and 50% of the target volume decreased by 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.05, respectively. The mean percentage of the target volume covered by the prescribed dose decreased by 2.8 ± 4.4%. CONCLUSION: We demonstrated the intra-fractional motion-managed treatment strategy in breath-hold Ethos CT-STAR/SBRT using optical surface imaging and CBCT. While the controlled residual tumor motion measured at 3.5 mm exceeded the predetermined setup value of 2 mm, it is important to note that this motion still fell within the clinically acceptable range defined by the PTV margin of 5 mm. Nonetheless, additional caution is needed with intra-fractional motion management in breath-hold Ethos CT-STAR/SBRT using optical surface imaging and CBCT.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/patologia , Estudos de Viabilidade , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração , Radioterapia Guiada por Imagem/métodos , Radiocirurgia/métodos , Tomografia Computadorizada de Feixe Cônico/métodos
17.
J Appl Clin Med Phys ; 25(4): e14241, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38193605

RESUMO

PURPOSE: It is challenging to achieve appropriate target coverage of the prostate with Image Guided Radiation Therapy (IGRT) while simultaneously constraining rectal doses within planned values when there is significant variability in rectal filling and shape. We investigated if rectum planning goals can be fulfilled using rigid CBCT-based on-board alignment to account for interfraction rectal deformations. METHODS: Delivered rectal doses corresponding to prostate alignment ("PR") and anterior rectum alignment ("AR") for 239 daily treatments from 13 patients are reported. Rectal doses were estimated by rigidly mapping the planned dose on the daily CT derived from the daily CBCT according to respective alignment shifts. Rectum V95% (rV95%) was used for analyses. RESULTS: Compared to "PR", "AR" alignment increased rV95% for an average of 34.4% across all patients. rV95% (cc) averaged over all fractions was significant from planning values for 10/13 patients for "PR" and for 9/13 for "AR". 3/13 patients had reproducible anatomy. Of patients with non-reproducible anatomy, three had dosimetrically more favorable, while seven had less favorable anatomies. Most shift differences (82.3%) between the "PR" and "AR" alignments larger than 2 mm resulted in rV95% changes larger than 2 cc. Most shift differences (82.2%) of 2 mm or less between the "PR" and "AR" alignments resulted in rV95% changes less than 2 cc. The average percentage of fractions among patients in which anterior or posterior shifts for "AR" and "PR" alignment was larger than the PTV margins was 9.1% (0.0%-37.5%) and 1.3% (0%-10%). CONCLUSION: Rectal deformation and subsequent inconsistent interfraction separation between prostate and rectal wall translate into anatomical changes that cannot always be mitigated with rigid alignment. If systematic differences exist due to a non-reproducible planning anatomy, attempts to restore the planned rectal doses through anterior rectum alignment produce rather small improvements and may result in unacceptable target underdosage.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia Guiada por Imagem/métodos , Próstata/diagnóstico por imagem , Reto , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
18.
Clin Oncol (R Coll Radiol) ; 36(3): 165-172, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38246849

RESUMO

AIMS: Standard of care radiotherapy for locally advanced cervical cancer includes large margins to ensure the uterocervix remains within the treatment fields over the course of treatment. Daily online cone-beam adaptive radiotherapy corrects for interfractional changes by adjusting the plan to match the target position during each treatment session, thus allowing for significantly reduced clinical target volume (CTV) to planning target volume (PTV) margins. We hypothesise that reduced margins from daily online adaptive radiotherapy will reduce organ at risk dose without compromising target coverage. MATERIALS AND METHODS: Ten patients with cervical cancer (stage IIB-IIIC2) were treated with definitive chemoradiation using daily online cone-beam adaptive radiotherapy in 25-27 fractions. Initial and all adapted treatment plans were generated with CTV to PTV margins versus standard of care image-guided radiotherapy (IGRT) plans as follows: cervix/uterus/gross tumour volume (0.5 versus 1.5 cm), parametria/vagina (0.5 versus 1.0 cm) and nodal chains and gross nodes (0.5 versus 0.5 cm). IGRT plans were created and copied to synthetic computed tomography scans and contours generated from each daily adapted fraction. The dosimetry of each clinically treated online adapted fraction was compared with emulated IGRT plans. Statistical significance was defined as P < 0.05. RESULTS: Daily online cone-beam adaptive radiotherapy significantly improves bowel bag dosimetry compared with IGRT, with a reduction in V40 by an average of 91.3 cm3 [V40 (-6.2%) and V45 (-6.1%)]. The daily adapted plans showed significant improvements in bladder and rectum [V40 (-25.2% and -36.0%) and V30 (-9.7% and -17.1%), respectively]. Additionally, bone marrow had a significantly reduced dose [V10 (-2.7%) and V20 (-3.3%)]. Daily online cone-beam adaptive radiotherapy improved uterocervix CTV coverage and reduced hotspots compared with IGRT [D95% (+1.6%) and Dmax (-0.9%)]. CONCLUSIONS: Reduced CTV to PTV margins achievable with daily online adaptive radiotherapy improves organ at risk dosimetry and target coverage when compared with standard of care IGRT for locally advanced cervical cancer. The clinical impact of improved dosimetry is currently undergoing investigation.


Assuntos
Pyrus , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica
19.
Radiol Oncol ; 58(1): 124-132, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38183274

RESUMO

BACKGROUND: To retrospectively analyze the accuracy of radiotherapy using cone beam computed tomography (CBCT), Styrofoam fixation, and breast bracket fixation in the chest wall target area and supraclavicular lymphatic drainage area (supraclavicular target area) of patients with breast cancer.and compare the setting efficiency and comfort satisfaction. PATIENTS AND METHODS: A total of 65 patients with postoperative lymphatic metastasis of breast cancer, including 36 cases of Styrofoam fixation and 29 cases of breast bracket fixation, were recruited from March 2021 to August 2022 and retrospectively analyzed. All the patients underwent CBCT scans weekly, and the setup errors of the chest wall and supraclavicular target volume were compared and recorded. The planning target volume (PTV) margins of the two groups were calculated using the correlation MPTV = 2.5Σ + 0.7σ. The setup time and comfort satisfaction scores of the two groups were recorded and analyzed. The correlations among errors in each direction were analyzed using the Pearson correlation analysis. RESULTS: There was a significant difference in the left-right direction (X) axis of the chest wall target area between the Styrofoam and breast bracket groups (1.59 ± 1.47 mm vs. 2.05 ± 1.64 mm, P = 0.012). There were statistical differences in the ventrodorsal direction (Z) and bed angle of the supraclavicular target area, the data were (1.36 ± 1.27 mm vs. 1.75 ± 1.55 mm, P = 0.046; 0.47 ± 0.47° vs. 0.66 ± 0.59°, P = 0.006, respectively). In the X, Y, and Z directions, the respective PTV margins of the two groups in the chest wall target area were 5.01 mm, 5.99 mm, and 5.47 mm in the Styrofoam group, while those in the breast bracket group were 6.10 mm, 6.34 mm, and 6.10 mm, respectively. Moreover, the PTV margins of the supraclavicular target in the three directions were 3.69 mm, 3.86 mm, and 4.28 mm in the Styrofoam group, while those in the breast bracket group were 3.99 mm, 3.72 mm, and 5.45 mm, respectively. The setup time of the two groups was 3.4 ± 1.1 min and 5.5 ± 3.1 min (P = 0.007). The subjective comfort satisfaction scores of the two groups were 27.50 ± 1.24 and 25.44 ± 1.23 (P < 0.001). CONCLUSIONS: The application of Styrofoam fixation in radiotherapy of breast cancer in the supraclavicular lymph node area has several advantages as compared to breast bracket fixation, including higher positioning accuracy, smaller external expansion boundary, improved work efficiency, and patients' comfort, which might provide a reference for clinical work.


Assuntos
Neoplasias da Mama , Poliestirenos , Radioterapia Guiada por Imagem , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Estudos Retrospectivos , Radioterapia Guiada por Imagem/métodos , Metástase Linfática/radioterapia
20.
J Appl Clin Med Phys ; 25(2): e14263, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38268200

RESUMO

BACKGROUND: Surface-guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited. PURPOSE: To assess the clinical application and alignment agreement of SGRT with CT-on-rails (CTOR) and kV-2D image-guided radiation therapy (IGRT) for breast treatment using proton therapy. METHODS: Four patients receiving breast or chest wall treatment with proton therapy were the subjects of this study. Patient #1's IGRT modalities were a combination of kV-2D and CTOR. CTOR was the only imaging modality for patients #2 and #3, and kV-2D was the only imaging modality for patient #4. The patients' respiratory motions were assessed using a 2-min surface position recorded by the SGRT system during treatment. SGRT offsets reported after IGRT shifts were recorded for each fraction of treatment. The agreement between SGRT and either kV-2D or CTOR was evaluated. RESULTS: The respiratory motion amplitude was <4 mm in translation and <2.0° in rotation for all patients. The mean and maximum amplitude of SGRT offsets after application of IGRT shifts were ≤(2.6 mm, 1.6° ) and (6.8 mm, 4.5° ) relative to kV-2D-based IGRT; ≤(3.0 mm, 2.6° ) and (5.0 mm, 4.7° ) relative to CTOR-based IGRT without breast tissue inflammation. For patient #3, breast inflammation was observed for the last three fractions of treatment, and the maximum SGRT offsets post CTOR shifts were up to (14.0 mm, 5.2° ). CONCLUSIONS: Due to the overall agreement between SGRT and IGRT within reasonable tolerance, SGRT has the potential to serve as a valuable auxiliary IGRT tool for proton breast treatment and may improve the efficiency of proton breast treatment.


Assuntos
Radioterapia Guiada por Imagem , Parede Torácica , Humanos , Radioterapia Guiada por Imagem/métodos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Inflamação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...